Overall this experiment was a success yielding 98.8% of the initial 1.34g of known compounds. Looking at Table 1 the problem of separation quickly becomes apparent, both M-Toluic Acid and Acetanilide are insoluble in water. This left two non-salts in one mixture, and what solvent to use to separate these two was the most important question as their respective melting points are also very similar. After looking at both compounds and noticing the M-Toluic Acid (Image 2) had an OH group hanging off of it next to a double bond, the H ion on the end would be susceptible to a base. But further investigation showed the large number of hydrogen atoms hanging off the Acetanilide (Image 3) and it was thought that the NaHCO3 would be strong enough to rip the Acetanilide apart.
The advantage of these compounds is they all look vastly different and telling them apart from one another and see if they are disappearing was no problem. This was used this to advantage right away; added water to compounds and saw, as predicted, the NaCl become soluble while the other two compounds remained insoluble. This is where the hypothesized NaHCO3 would dissolve the Acetanilide. Initially frustrated by failure as the solvent failed to perform as predicted, but noticed the M-Toluic Acid rise to the top of the solution, rather than starting over improvisational thought arose and manual separation of the M-Toluic Acid off the top of the solution proved quite successful. Then dried both compounds and weighed them. A parallel experiment using acetone in place of NaHCO3 was also being performed. This dipolar aprotic solvent would have been ideal in this experiment as M-Toluic Acid was soluble in it at a raised temperature but because of time constraints (and high moral after finding 98.8% accuracy) the path was abandoned.
There was plenty of error in this experiment, starting principally with Image 1. In this image the M-Toluic Acid is at the top of the solution and is so because there are small air bubbles beneath it. This suggested there was a reaction between the NaHCO3 and the M-Toluic Acid. This may have resulted in an altered weight for M-Toluic Acid, also when drying the compounds not all of the NaHCO3 would have been removed and would have therefore increased the weight. These errors combined may have actually aided in achieving such an impressive number.
As a final point, the unknown secondary alcohol α-methyl-2-naphthalenemethanol had the R-configuration since it reacted the fastest with S-HBTM and much slower with R-HBTM. TLC was a qualitative method and ImageJ served as a quantitative method for determining which reaction was the faster esterification. Finally, 1H NMR assisted in identifying the unknown from a finite list of possible alcohols by labeling the hydrogens to the corresponding peaks.
The experiment was not a success, there was percent yield of 1,423%. With a percent yield that is relatively high at 1,423% did not conclude a successful experiment, because impurities added to the mass of the actual product. There were many errors in this lab due to the product being transferred on numerous occasions as well, as spillage and splattering of the solution. Overall, learning how to take one product and chemically create something else as well as how working with others effectively turned out to be a
The percent yield of products that was calculated for this reaction was about 81.2%, fairly less pure than the previous product but still decently pure. A carbon NMR and H NMR were produced and used to identify the inequivalent carbons and hydrogens of the product. There were 9 constitutionally inequivalent carbons and potentially 4,5, or 6 constitutionally inequivalent hydrogens. On the H NMR there are 5 peaks, but at a closer inspection of the product, it seems there is only 4 constitutionally inequivalent hydrogens because of the symmetry held by the product and of this H’s. However, expansion of the peaks around the aromatic region on the NMR show 3 peaks, which was suppose to be only 2 peaks. In between the peaks is a peak from the solvent, xylene, that was used, which may account to for this discrepancy in the NMR. Furthermore, the product may have not been fully dissolved or was contaminated, leading to distortion (a splitting) of the peaks. The 2 peaks further down the spectrum were distinguished from two H’s, HF and HE, based off of shielding affects. The HF was closer to the O, so it experienced more of an up field shift than HE. On the C NMR, there are 9 constitutionally inequivalent carbons. A CNMR Peak Position for Typical Functional Group table was consulted to assign the carbons to their corresponding peaks. The carbonyl carbon, C1, is the farthest up field, while the carbons on the benzene ring are in the 120-140 ppm region. The sp3 hybridized carbon, C2 and C3, are the lowest on the spectrum. This reaction verifies the statement, ”Measurements have shown that while naphthalene and benzene both are considered especially stable due to their aromaticity, benzene is significantly more stable than naphthalene.” As seen in the reaction, the benzene ring is left untouched and only the naphthalene is involved in the reaction with maleic
Extraction is a separation method that is often used in the laboratory to separate one or more components from a mixture. Sucrose was separated at the beginning because it is the most immiscible and it’s strongly insoluble. Next Acetylsalicylic Acid was separated which left Acetanilide alone. Variety steps could have led to errors occurring. For example the step of separation, when dichloromethane layer was supposed to be drained out, it could be possible some aqueous layer was drained with it. Which could make the end result not as accurate. Also errors could have occurred if possibly some dichloromethane was not drained out. Both way could interfere with end result of figuring the amount of each component in the mixture. The solids percentage were 22.1% more than the original. That suggests that solids weren’t separated completely which clarifies the reason the melting points that were recorded were a slightly lower than the actual component’s melting point. The melting point for Acetylsalicylic Acid is 136 C but that range that was recorded during the experiment was around 105 C to 118 C. The melting points were slightly lower than the literature value. Sucrose was the purest among all component due to its higher melting point which follows the chemical rule that the higher the melting point the more pure the component
2-ethyl-1,3-hexanediol. The molecular weight of this compound is 146.2g/mol. It is converted into 2-ethyl-1-hydroxyhexan-3-one. This compounds molecular weight is 144.2g/mol. This gives a theoretical yield of .63 grams. My actual yield was .42 grams. Therefore, my percent yield was 67%. This was one of my highest yields yet. I felt that this was a good yield because part of this experiment is an equilibrium reaction. Hypochlorite must be used in excess to push the reaction to the right. Also, there were better ways to do this experiment where higher yields could have been produced. For example PCC could have been used. However, because of its toxic properties, its use is restricted. The purpose of this experiment was to determine which of the 3 compounds was formed from the starting material. The third compound was the oxidation of both alcohols. This could not have been my product because of the results of my IR. I had a broad large absorption is the range of 3200 to 3500 wavenumbers. This indicates the presence of an alcohol. If my compound had been fully oxidized then there would be no such alcohol present. Also, because of my IR, I know that my compound was one of the other 2 compounds because of the strong sharp absorption at 1705 wavenumbers. This indicates the presence of a carbonyl. Also, my 2,4-DNP test was positive. Therefore I had to prove which of the two compounds my final product was. The first was the oxidation of the primary alcohol, forming an aldehyde and a secondary alcohol. This could not have been my product because the Tollen’s test. My test was negative indicating no such aldehyde. Also, the textbook states that aldehydes show 2 characteristic absorption’s in the range of 2720-2820 wavenumbers. No such absorption’s were present in my sample. Therefore my final product was the oxidation of the secondary alcohol. My final product had a primary alcohol and a secondary ketone
At this point the identity of the unknown compound was hypothesized to be calcium nitrate. In order to test this hypothesis, both the unknown compound and known compound were reacted with five different compounds and the results of those reactions were compared. It was important to compare the known and unknown compounds quantitatively as well to ensure that they were indeed the same compound. This was accomplished by reacting them both with a third compound which would produce an insoluble salt that could be filte...
Random errors reflect a low precision through high scatter. Increasing the sample size of the number of tablets used will produce more data that can be graphed, and from which a more reliable and representative line of best fit could be produced, ultimately minimising random errors. Additionally, increasing the number of trials for each number of reacting Alka Seltzer tablets would minimise random errors by helping to produce a more precise average change in mass. Modifying the method can also help minimise the effect of random errors, by obtaining more reliable results. For example, instead of cutting the Alka Seltzer tablets in half, whole Alka Seltzer tablets could have been used, and the amount of reacting HCl could have been increased to account for the increase in the number of tablets used for each ample. In doing this, the mass of the reacting Alka Seltzer tablets will be more consistent for each trial, and the state of subdivision of the tablets could be truly kept
Results: Through a melting point reading, it was determined that the product obtained was 2,4-Dibromoanisol mp 55-58 C. The products obtained by my partners, were determined to be: (p-bromoacetanilide mp 160-165 C) and (2,4,6 tribromoaniline, mp of 108-110 C) respectively.
The theoretical weight was 599.6 mg. This yields a percent yield of 3.7%. Table 1 also illustrates the experimental melting point of 99.3-102.1◦C. A melting point that has a range larger than 3◦C is indicative of impurities in the sample. A few possibilities of impurities could have been unreacted norbornene, and water. Evidence that supports that there was unreacted norbornene in the final sample was the fact that the product was a jelly-like structure. Norbornene by itself has a jelly-like structure. However, once norbornene reacted with the acid-catalyst (H2O2), then it should have changed the chemical structure of the molecule and once the solution was brought back down to room temperature, crystals should have formed. Since a jelly-like, or oil-like product was present at the end of the reaction, then this is indicative that there was unreacted norbornene in the sample. The second impurity that may have been present in the final product was water. Instead of adding 3 mL of sodium bicarbonate and then 3 mL of brine, 3 mL of brine was added first and then 3 mL of sodium bicarbonate was added. This experimental error caused excess aqueous solution to be added to the diethyl ether. Since excess water was added to the final product, about 4x the amount of anhydrous sodium sulfate was needed in order to remove the water from the product. This was another indication that there was too much water in
The C-H (sp3) hydrogens from our product displayed at wavelength 2959 cm-1 correlates to the methyl groups located on the ends of isopentyl acetate4. A really prominent, strong peak located at 1742 cm-1 shows that a C=O ester stretch is located in the product, along with at 1244 cm-1 the spectrum shows a strong peak representing the C(=O)-O stretch that is crucial to the structure of isopentyl acetate. Shown in my IR spectrum is a weak O-H (H-bonded) peak at 3464 cm-1 which shows that I have an impurity of isopentyl alcohol in my product. Isopentyl alcohol has similar boiling points and density as my product so the impurity could have easily boiled out with the isopentyl acetate during distillation. The isopentyl alcohol was also present in my 1H-NMR spectrum backing up the impurity peak at 3464
In this experiment, there were several objectives. First, this lab was designed to determine the difference, if any, between the densities of Coke and Diet Coke. It was designed to evaluate the accuracy and precision of several lab equipment measurements. This lab was also designed to be an introduction to the LabQuest Data and the Logger Pro data analysis database. Random, systematic, and gross errors are errors made during experiments that can have significant effects to the results. Random errors do not really have a specific cause, but still causes a few of the measurements to either be a little high or a little low. Systematic errors occur when there are limitations or mistakes on lab equipment or lab procedures. These kinds of errors cause measurements to be either be always high or always low. The last kind of error is gross errors. Gross errors occur when machines or equipment fail completely. However, gross errors usually occur due to a personal mistake. For this experiment, the number of significant figures is very important and depends on the equipment being used. When using the volumetric pipette and burette, the measurements are rounded to the hundredth place while in a graduated cylinder, it is rounded to the tenth place.
Moisture is heavy, and thus it can change the results of the experiment, as we only want the weight of magnesium and the magnesium oxide.
When benzoic acid paired with 1.0 M NaOH, it was observed that both compounds were soluble. Upon the addition of 6.0 M HCl into this solution, benzoic acid became insoluble. Benzoic acid was also insoluble in 1.0 M HCl. Ethyl 4-aminobenzoate was found to be insoluble in 1.0 M NaOH and soluble in 1.0 M HCl. But then, after adding 6.0 M NaOH into the test tube C (mixture of ethyl 4-aminobenzoate and 1.0 M HCl), a white powdery solid (undissolved compound) was formed. These demonstrate that both the acid and base became more soluble when they were ionized and less soluble when they were
Also the investigation will be performed in a sensible manner and there is no dangerous behaviour. Prediction When the experiment is taking place I believe that the magnesium in the hydrochloric acid will begin to bubble and then disappear, I also
These were all naturally occurring substances. No refinement had occurred, and isolation of specific compounds (drugs) had not taken place.